Operation Manual

For

NDJ-1 Rotary Viscometer

MADE  IN  CHINA

Thank you for using NDJ-1 Rotary Viscometer. NDJ-1 is easy to use, in order to install and operate accuray, and make full use of product features, we suggest you to read the manual before using.

· The company possesses the final interpretation power.

· The company reserves the power of amending technical rules without prior notice.

· The company reserves the power to amend the manual without further notice.

· May not be translated into other languages, reproduction prohibited without written permission. 

               

               Cataloge

1General……………………………………………………

2Main technical data…………………………………………

3Principle………………………………………………

4Installation……………………………………………………

5Operation procedures………………………

6Precaution………………………………………………

Packing List ……………………………………………………

1. General

NDJ-1 rotary viscometer is a new instrument used for determining the liquid viscose capacity and the absolute viscosity. NDJ-1 has been widely used to determine and measure the liquid viscosity in many applications such as grease, painting, plastic, pharmacy and adhesives. It is a precision instrument to monitor and control the stable quality of products in the manufacturing.

2. Main technical data

1) Measurement range: 10-100.000 mPa·s 

2) Rotor specification: 0, 1, 2, 3, 4, 5, five kind rotor (0# rotor could measure the viscometer from low viscometer to 0.1 mPa·s)

3) Measurement error: ±5% (Newton liquid)

4) Power supply: Voltage--220±22V, Frequency50 Hz±0.5Hz

5) Dimensions: 300 mm ×300 mm × 450 mm

6) Net weight: 1.5 Kg (the base not included)

3. Principle

1) Figure 1Synchronous motor rotates with stable rate, connect scale disk, through hairspring and rotating shaft, drives rotors to rotate. The rotors will subject to a torque moment proportional to liquid viscosity because of the liquid viscose hysteresis. The torque moment will be measured by the sensors and processed into the viscosity and shown on the display.

2) Rate can be changed by using gear system and clutch, operated by rotary knob, four optional velocity.

3) According to different equipments, different rotors (Five rotors: NO.0-NO.4) will be attached, it can be select with the velocity according to the viscosity of the liquid.

4) The fixed control gear of pointer are used for accurate reading. When the rate is so fast (30 rpm, 60 rpm) that you can not get the reading while it rotated, press pointer joystickfix the pointer in order to get the reading.

5) The rotor bracket is used for the protection of rotors and the stability of the measurement, a more reliable measuring result can be made by using the protection bracket. 

6) It can be used as a portable instrument, assigned fixed bracket and elevating system. Generally, it should be fixed when determine small amount or the temperature is fixed in the laboratory.

7) The instrument has gears and damping elevate mechanism. It is stable for instrument lifting.

8) The whole set of instrument has good quakeproof packing to ensure the precision of instrument.

Installation

1. Take out the bracket, package, stanchion and so on from the packaging.

2. Screw the column to the threaded hole behind the bracket, and put the tooth profile surface in the column facing front the bracket. Screw the hex nut tight by wrench to prevent the column running.

3. Rotational move the lifting chuck knob to check the flexibility and self-looking of lifting chuck. Found the lifting chuck too loosen and too tight phenomenon, can be used hex nut wrench to adjust the tight screw. So that it can lift from top to bottom. And it is suitable for tight to prevent the situation of automatically falling after installing the viscometer.

4. Take out viscometer form package and mount it on the lifting collettight it by handle setscrew to avoid loosen(as level as possible), link the power supply, take away the rubber band on the pointer joystick, screw the nut of protecting-cap loosen under the instrument, take away the protecting -cap.

5. Adjust the adjustment screw and put the rotor into the liquid to be measured till the level mark on the rotor reach the liquid surface.

Operation procedures

1. Prepare the liquid to be measured and put it into a glass beaker or a right angle container with the diameter not smaller than 70 mm, height not smaller than 130mm, take care of the liquid temperature.

2. Mount the protection bracket on instrument, turning right for mounting, turning left for removing.

3. Screw the selected rotor into connecting rod, turning right for mounting, turning left for removing , Adjust the lifting screw and put the rotor into the liquid to be measured till the level mark on the rotor reach the liquid surface. Connect power supply, turn on the equipment, screw the speed knob, select velocity, relax pointer joystick, reading data can be displayed (about 20~30 seconds) when the pointer becomes stable. Press the pointer joystick after pointer becoming stable, cut power supply, then get the reading data. If the pointer isnt in reading window after motor stop, you can press pointer joystick unceasingly, open or close the motor time after time, after practice, you can operate it familiarly.

4. When the reading data is too high or too low, the rotor or the rate can be changed, make sure the reading is between 20 and 80.

5. Choice of range, coefficient, rotor and rate:

5.1 Estimate approximay the viscose range, then select the rotor and the velocity based on the range table given below:

For example, the viscosity of liquid is about 3000 mPa·s the settings should be as following:  

rotor 2 # with velocity of 6 rpm,

rotor 3 # with velocity 0f 30 rpm

5.2 If the viscosity of liquid can not be estimated, it should take a high value for real measurement, the rotor selection should be made from smaller to larger with their number from higher to lower. In general, high viscosity should use smaller rotor with slower velocity, lower viscosity use lager rotor with faster velocity.

5.3 Coefficient: the reading must be multiplied the specific coefficient in the coefficient table in order to get the absolute viscosity.

   That is: 

            absolute viscosity

            coefficient

            reading ( deflection angle)

   5.4 Amendment of frequency error: when the power frequency is inaccurate, you can amendment it according to the formula below:

      Actual viscosity= instruction viscosity*nominal frequency/ actual frequency

Velocity

Range

Rotor

60

30

12

6

1

100

200

500

1000

2

500

1000

2500

5000

3

2000

4000

10000

20000

4

10000

20000

50000

100000

   5.5 

5.6 Coefficient table: 

        Rpm

Rotor

60

30

12

6

1

1

2

5

10

2

5

10

25

50

3

20

40

100

200

4

100

200

500

1000

 

Precaution

1. This instrument is limited to the room temperatures

2. This instrument should be used under the designed voltage and frequency and their allowable error ranges, or incorrect results could be resulted.

3. Using the bracket fix the instrument in order to determine accuray. Handheld operation: keep the instrument stable and level.

4. Care should be taken for mounting or removing rotors, slightly and lift the connecting screw bolt to avoid a transverse force acting on rotor to cause it bending.

5. The instrument mounted with rotor should not be revolved.

6. Don’t run the motor when the pointer joystick is not pressed.

7. Keep cleaned on screws and connecting points between rotor and connecting bolt rod, or a unstable rotation could be caused in the real measurement.

8. Use hand to hold the instrument when lifting up or moving down to avoid dropping it.

9. After completing measurement each time, the rotor should be fully cleaned (rotor should be removed from instrument for cleaning), then place it on the protection bracket.

10. Unauthorized removing or replacing the instrument part, and applying lubricates are not allowable.

11. When moving or shipping instrument, put on the yellow caver cap and lift the connecting bolt rod and screw the bolt on the cap tightly.

12. Suspension, emulsion or polymer and other high viscosity liquids are non-Newton liquids, their viscosity will change with shear velocity and time, it is normal for their measured inconsistent results under the selected rotor and velocity and time, and it is not resulted from the instrument problems (in general, the rotor and velocity and time should be specified for non-Newton liquids).  

13. The cautions should be taken for followings to obtain a good measuring reault:

(1) Accuray control the temperature of liquid to be measured;

(2) Make temperature of rotor and protection bracket same as liquid;

(3) Ensure the liquid homogeneity and without bubbles;

(4) Put the rotor located on the center of the liquid container in real measurement;

(5) Remove bubbles adhered on the rotor when put it into liquid;

(6) When change the rotor or rate, keep between 30~90 as possible.

(7) Use rotor protection bracket for measurement;

(8) Ensure rotor and connecting screw rod cleaned;

(9) Amend according to the amending formula when power frequency is not exact.

(10) When pointer is stable, reading with the same angle of view.

(11) Adjust level bubble exactly, move the instrument slowly, keep the instrument stable.

(12) Strictly follow the operation instruction for measurement.

Packing List

1) NDJ-1 Digital Rotary Viscometer           1 Qt.

2) Rotors, 1#, 2#, 3# and 4#                   1 Qt of each

3) Protection bracket                       1 Qt.

4) Bracket                                1 Qt.

5) Adjusting screw                         3 Qt.

6) Operation manual                        1 Qt.

7) License                                1 Qt.

8) Warranty card                           1 Qt.

上海平軒科學儀器有限公司

上海平軒科學儀器有限公司

工廠地址:上海市嘉定區南翔德園路1259弄18號

©2018 版權所有:上海平軒科學儀器有限公司  備案號:滬ICP備10019381號-1  總訪問量:1610477  站點地圖  技術支持:化工儀器網  管理登陸

主站蜘蛛池模板: 成人国内精品久久久久影 | 337p粉嫩日本欧洲亚洲大胆 | 可以看av的网站 | 3d动漫精品啪啪一区二区下载 | 久久精品无码精品免费专区 | 国产亚洲精品影视在线 | 亚洲人成网站在线观看播放 | 欧美一级高潮片免费的 | 亚洲精品无码鲁网午夜 | 色婷婷欧美在线播放内射 | 亚洲aaa视频| 日本真人做人试看60分钟 | 无码少妇一区二区三区芒果 | 无码人妻丰满熟妇区视频 | 欧美日韩成人 | 国产精品久久久久aaaa九色 | 欧洲在线观看 | 婷婷在线五月 | 久久久久久久女国产乱让韩 | 东北老女人高潮大叫对白 | 亚洲精品欧美一区二区三区 | 久久精精 | 国产精品福利资源在线 | 天天艹日日干 | 国产爆乳美女娇喘呻吟 | 国产精品无码人妻无码色情多人 | 中文字幕在线精品视频入口一区 | 理论片午午伦夜理片在线播放 | 日韩av片免费播放 | 亚洲日韩欧美内射姐弟 | 欧美成人免费高清二区三区 | 亚洲夜夜爽 | 亚洲欧美日韩国产制服另类 | 亚洲日韩精品无码一区二区三区 | 日本理伦片午夜理伦片 | 国产亚洲精品久久久久蜜臀 | 日韩精品久久久久久免费 | 国产精品网址你懂的 | 国产精品美女久久久久av爽李琼 | 亚洲国产精品一区二区成人片 | av无码小缝喷白浆在线观看 | 午夜精品久久久久久久无码 | 国精产品999一区二区三区有限 | 国产一级在线看 | 达达兔午夜起神影院在线观看麻烦 | 超级97碰碰碰碰久久久久最新 | 亚洲人成网站999久久久综合 | 国产 日韩 欧美 高清 | 日本少妇肉体裸交xxx | 国产亚洲精品一区二区三区 | 欧美日韩亚洲国内综合网俺 | 荫蒂添的好舒服视频囗交 | 午夜色大片在线观看免费 | 女人裸体做爰免费视频 | 五级黄高潮片90分钟视频 | 成人性视频免费网站 | 91看片在线免费观看 | 成人综合婷婷国产精品久久蜜臀 | 水蜜桃亚洲一二三四在线 | 人人插人人澡 | 免费视频欧美无人区码 | 久久九九精品一区二区 | 亚洲成av人片一区二区小说 | 黄色激情网站 | 国产欧美日韩 | 日本wwww视频 | 欧美 亚洲 国产 另类 | 99国产精品人妻噜啊噜 | 草草视频手机在线观看视频 | 日本玖玖| 亚洲精品人人 | 久久国产一区二区三区 | 牛牛a级毛片在线播放 | 毛片一区二区三区无码 | 91麻豆精品一二三区在线 | 一级做a爰片久久毛片看看 欧美日韩精品国产一区二区 | 邪不压正免费观看完整高清视频 | 欧美一区二区精品 | 午夜精品久久久久久99热 | 日韩在线 在线播放 | 久久99热久久精品在线6 | 成人免费看av | 亚洲一区二区三区在线播放 | 国产精品美女久久久久久久网站 | 大地资源网中文第五页 | 大肉大捧一进一出好爽视频动漫 | 亚洲精品无码mⅴ在线观看 亚洲精品无码mv在线观看网站 | av无码人妻一区二区三区牛牛 | 国产精品一区二区av | 狠狠色老熟妇老熟女 | 久久综合九色综合欧美狠狠 | 新神奇四侠免费完整版在线观看 | 黑粗硬大欧美 | av在线第一页 | 色婷婷综合网 | 狠狠久久| 亚洲妇熟xxxx妇色黄 | 精品福利视频一区二区三区 | 国产精品无码一区二区三区不卡 |